All Questions
Tagged with vmware-esxi hp
79
questions
0
votes
0
answers
27
views
HP P440AR version 7.0 with Samsung 870 1TB drives - RAID6 esxi 8.02
I have a ProLiant ML350 Gen9 with P440Ar Raid controler, on which i added 6 Samsung 870PRO 1TB drives and put them into RAID 6 configuration with additional SSD drive with esxi 8.02
Everything went ...
1
vote
1
answer
43
views
Netapp Storage to HP Nimble cloud
We have a working Netapp Setup with FAS2720 9.7P9 Version connected to Fujitsu ESXi (VMWare 5.5). With multiple VMs running on 3 ESXi Systems but they are residing entirely on Netapp Storage.
We are ...
1
vote
1
answer
807
views
ESXi command to check power supply status?
I need to check the power suppliers status of an HP ProLiant DL380 by ESXi to create/get a note that informs me if one dies.
By using the command esxcli hardware ipmi sdr list i'm getting pretty close ...
1
vote
1
answer
2k
views
Installing ESXi 6.7 on HP Gen9 Warning vmFileSystem: Slow refresh failed. Cannot open volume: vmfs/volumes/
Durin installation of ESXi 6.7 (HPE Custom ISO) on HPE Gen9 server I see this message:
And it is stuck on this "Scanning System":
Gathering additional system information. This may take a ...
1
vote
2
answers
308
views
Newly added drives do not appear in the raid array list (hp server and ESXi)
I recently added two physical drives into my hp server (port 2). I also add them to the raid array list, but they don't appear in it:
and:
How can I add Disk 5,6 to the raid5 array list?
is ...
-1
votes
1
answer
169
views
DL180 G6 server suddenly loses access to SSD datastore on ESXi 6.0 [closed]
I've currently got a HP ProLiant DL180 G6 server. It originally came with a Smart Array P410i raid card, which I used to create a bunch of RAID0 disks (one SSD for my ESXi datastore and a couple of ...
1
vote
2
answers
3k
views
DL380 G9 - ESXi v6 u3 showing SCSI disk as normal,degraded
We have installed Vmware ESXi v6 u3 on a DL380 G9. We did the raid in the Intelligent provisioning during system startup, after which we did the Install. But all the volumes created are showing up as ...
3
votes
1
answer
798
views
Remove two physical drives from raid 5 array (4 disks)
I'm using a G6 hp server with 4 physical drives and p410 raid controller. I set up raid5 array with 3 physical drives,but one of them has been failed and becouse of this, I am in the Interim recovery ...
1
vote
2
answers
3k
views
Trouble creating a data store on ESXI 6.5 u1
I have a RAID 6 array (HP p822 controller v8.0 firmware) that I just added to my ESXI server. When I went to create a new data store I noticed it showed 2.92gb free of 10.92tb. This is a new array, ...
1
vote
1
answer
2k
views
Configuring RAID HP P822 Smart Array controller in Supermicro system, possible?
I have a very strange mashup of parts that I am trying to get working for a project. Due to a windfall from a client who was getting rid of hardware, I became the proud owner of a HP P822 controller.
...
-1
votes
2
answers
59
views
Server reboots at booting linux based softwares
We have a dl380p gen8 hp server and it was just working fine till one reboot that we don't know what happened but as a result our ESXi os does not boot anymore, it just goes to reboot after loading ...
1
vote
2
answers
3k
views
HP Smart Array P400 Write Cache not Enabling on VMware ESXi 5.5 Running on ProLiant DL380 G6
I am trying to get write caching enabled on a Smart Array P400 even though there is no battery backup. We have a large building wide UPS backed up by a generator so the likelihood of loosing power is ...
2
votes
1
answer
2k
views
Is it possible to trunk ESXi 6.5 with HP 1820-48G?
I am trying to setup trunk between those two (ESXi 6.5 with HP 1820-48G) and nothing seems to work.
I have read vmware kb article (can not insert link) and no luck.
These are my setup options, brute ...
1
vote
2
answers
831
views
Daisy Chain HP D2600 HDD Array
So I've searched to see if anyone's tried this and it doesn't seem like they have (if they have they haven't documented it)
Setup
2 X HP ProLiant DL380 Gen 9 that share a HP MSA2040 SAS Dual ...
1
vote
4
answers
2k
views
ILO Update : Which version should we select?
We have a HP ProLiant DL160 Gen 8 server, with VMWare ESXi 6.0.0 actually installed on it.
We started to update it to VMWare ESXi 6.5, but the upgrade stopped, stating that we need to update the HP ...
-1
votes
1
answer
2k
views
diagnose purple screen of death ESX 6.0
Our server keeps crashing with a purple screen of death. I have tried interpreting the crash dumps but to no avail. I have an HP Proliant DL360 G7 with ESXi 6.0 running on it and I have other ...
0
votes
1
answer
3k
views
Why all LEDs of my HP Proliant DL380 G8 server flashing amber? [closed]
I'm using a HP Proliant DL380 G8 Server for 2 years with a VMWare ESXi 6u2 OS installed on it. Recently I have noticed that all systems insight display LEDs are flashing amber (screenshot in this link)...
2
votes
1
answer
192
views
HP Storageworks MSA60
I have an HP DL380 G5 with ESXi installed on a local RAID (146x3 RAID1) and it has attached an MSA60 storage. The server has issues so I will replace it with an identical machine. I know I will ...
1
vote
2
answers
201
views
VmWare / HP EVA: How many LUNs with one DiskGroup
I know that similar questions have been asked already, but I feel that they were on a rather theoretical level and are not quite applicable to my case.
We're operating 3 ESXi 6.0 hosts, all backed by ...
1
vote
2
answers
3k
views
not responding HP dl360 g7, Blinking RED health, Green Power, 1 Fan degraded
I recently toke over a role and handled this server dl360 g7. It has 2 power supplies all are ok. 1 degraded fan and others are all green. Installed with VMware esxi and and 3 vm installed. The server ...
3
votes
2
answers
2k
views
DL180 G6 - ESXI 6.0 - P410 - Lost access to volume Issue
We have a DL180 G6 Server with a P410 RAID Card. The server has the following three RAID arrays.
4x2TB - RAID 10
4x2TB - RAID 10
2x2TB - RAID 1
2x2TB HD's are configured as hot spares ...
10
votes
2
answers
10k
views
Can you connect a SAN directly to a HBA with Fibre Channel?
I am in the process of sourcing our company's first SAN as we have the need for high availability/shared storage. I have noticed fibre channel switches are extremely expensive, and for redundancy we ...
-1
votes
1
answer
134
views
Incorrect memory hp ProLiant ML110 G6 in VMWare
My ESXi server is report that it only has 8GB where as it actually has 16GB. I do not have physical access to the machine. How could I go about verifying this information? I am currently using the ...
1
vote
1
answer
1k
views
HP ProLiant ML350p Gen8 server keeps crashing (full speed fans)
I have a problem with a HP ProLiant ML350p Gen8 server. Most of the time it runs fine, but after several weeks of uptime, the server crashes out of the blue. This happened about 5 times now. When it ...
1
vote
4
answers
6k
views
Extremely slow disk speeds Centos 6
Setup looks as follows:
HP Proliant DL380 G7
6 x 3TB Sata drives (surveillance level) configured with hardware RAID 1+0 with the SATA controller on board. Model is Seagate SV35
192GB RAM
VMware ...
0
votes
1
answer
4k
views
How to find out driver and firmware version of my ESXi Fiber Channel HBA? (via SSH)
I have an ESXi 5.5 Server (HP DL380 G7).
How can i figure out the driver and firmeware version of my HP-QLOGIC Fiber Channel HBA via SSH?
I think i am too stupid... :-/
Thx for help.
2
votes
1
answer
999
views
ESXi very slow with WD reds
I have a small company and we offer tech support to small companies. I've been using the HP Gen8 MicroServer in most of them as a replacement of homebuilt computers for some time.
Sometimes customers ...
1
vote
0
answers
117
views
Ubuntu dd test becoming slow over time under ESXi 5.5
I have a HP DL320e running the custom HP build of ESXi 5.5.Guest is a Ubuntu server 14.04 with vmware tools installed. Write speeds to the two SSDs in RAID1 (disk added with thin provision) are great (...
3
votes
4
answers
10k
views
No LUN available to extend datastore
I have a HP DL380G5 with ESXi 5.5 and x4 146GB Sata disks in a RAID5 array. I have added one more disk to the server exactly as the other ones and, using SmartStart CD I managed to add the disk to the ...
1
vote
3
answers
5k
views
HP ProLiant disk failure, proceed or do not proceed
We have a HP proliant DL385 G7 server that’s a vmware ESXI host with a failed hard drive – the drive is a HP SAS-MDL, 7.2 K, 2TB. When we boot the server we get the attached message and we are not ...
-1
votes
1
answer
2k
views
HP DL360 G5 and using 3.5" sata drives OR USB [closed]
I have a HP DL360 G5 (1x 4core CPU, 4gb Ram, 4x 36gb SAS Hdd's) I am looking for some advice.
This server is just for home use to run some VM's with ESXI 5.1 for my home network and some testing of ...
4
votes
2
answers
1k
views
esxi passthrough storage adapter
I run ESXi 5.1.0 (HP version) on HP ProLiant ML310e G8 v2.
There are 2 Storage Adapters:
Smart Array P222
Dynamic Smart Array B120i
Storage Adapters are visible in ESXi/Storage Adapters.
Storage ...
5
votes
6
answers
25k
views
VMware ESXi error upon boot "Relocating modules and starting up the kernel"
Coming back from a 4-day weekend, I noticed the A/C had been turned off for the duration of the long weekend and the heat was around 80-82 degrees. The HP ProLiant DL185G5 was running but the system ...
0
votes
2
answers
3k
views
ESXi PCI passthrough on HP DL360 G5
I am running ESXi 5.5 on a DL360 G5 and the option for PCI passthrough shows 'Host does not support passthrough configuration'.
I have enabled VT in the BIOS under processor options and I have x64 ...
6
votes
1
answer
1k
views
Reusing a drive from an array
I read the question here Reusing Raid 5 Drive? but I'm not sure it applies 100% to my situation.
What is the standard practice when removing a drive from an array to use as a spare for another array? ...
2
votes
5
answers
16k
views
How can I fix Purple Screen of Death for ESX 5.5?
I have a ESX 5.5 installed on my HP Proliant DL 180 G6 with a configuration of
8X Intel(R) Xeon(R) CPU E5540 @ 2.53GHz, 24 Gb RAM.
Recently the server has crashed four times, showing the Purple ...
4
votes
1
answer
37k
views
Adding a local HDD to an ESXi host
I am trying to add a 4TB HDD to my ESXi server, but I can't find out how. I've tried following a few tutorials on the internet, which say to go to the configuration tab, storage, rescan the datastores ...
0
votes
2
answers
5k
views
Adding additional disks to HP P2000 SAS Storage
We have a 12 bay HP P2000 SAS Enclosure with 6 drives on RAID 5 installed. The drives are configured as 2 separate DataStores for a VMWare vSphere ESXi setup.
Now we want to add:
6 additional ...
3
votes
2
answers
10k
views
Very slow disk performance on HP P410 with RAID1+0
I have HP Microserver N54L, until recently i have used integrated software raid without problems.
I have 2x WD Black and 2x WD Red (non-pro) disks for my raid array. I also have SSD directly on the ...
0
votes
1
answer
649
views
Guest VMs Unknown after power outage on HP VSA
A remote office had a power outage tonight. When the power came up, both the Physical DC and the Physical ESXi Server came up. Connecting to vSphere, I can see the HP-VSA has started, but the other ...
8
votes
1
answer
5k
views
Identifying what caused a server reboot
I have an HP ProLiant DL380p Gen8 that is running VMWare ESXi 5.5. It has been rebooting itself at seemingly random intervals for the past 24 hours. There is only a single VM running, and even if I ...
1
vote
2
answers
6k
views
HP ProLiant Gen8 BIOS settings for VMware ESXi
What BIOS settings should be set on a HP BL460c Gen8 server so that ESXi 5.5 runs correctly?
1
vote
1
answer
8k
views
Upgrade the firmware of SAS HDD on DL380 G5?
I have a DL380 G5 server with 146GB single-port HDD (DG146ABAB). The HP Storage Array P400 controller is saying that firmware should be upgraded on these drives. I am running VMware ESX 5.1 (no ...
-2
votes
2
answers
169
views
Store VMs on the same Stick as ESXi
I've a HP N54L Microserver with an ESXi, which runs from the 16GB USB Stick.
In vSphere client I can't see any volumes, where I can store my VMs. And I think that ESXi never needs 16 GB to work.
Is ...
5
votes
1
answer
2k
views
ESXi v5.5 is having random crashes
HW:
Type: HP Proliant ML350 G5
RAM 22GB
CPU 1 x Intel Xenon E5405 2.00GHz
OP:
ESXi 5.5 just updated from 5.1 to try and fix the crashes occurring on ESXi 5.1 on same hardware.
I'm trying to find ...
2
votes
2
answers
4k
views
Unable to create datastore extent on VMware ESXi 5.5 - HP Smart Array P800
I have a HP P800 array controller connected to a HP MSA60 with 12x 1TB SATA drives installed. I provisioned a single array with 1 spare in ACU. I have followed this KB and created 4x 1.9TB logical ...
1
vote
1
answer
4k
views
How to check HP Smart array status on ESXi 5
I've been reading How to run the HP Online ACU CLI for Linux in ESXi 4.x & trying to figure out a way to see the RAID status of the server without having to restart it.
This is because, I've ...
1
vote
1
answer
547
views
Continuous I/O latency error on ESXi 5.0
Recently I posted a question on HP Proliant DL180 G6 - Smart Array P410, bay 11 error which the answers helped me to dig through. And today that I just noticed under my vSphere log which gives a ...
3
votes
4
answers
8k
views
HP Proliant DL180 G6 - Smart Array P410, bay 11 error
I've been trying to search over ther internet for a solution to fix this. I'm the new IT person for my organization and our previous IT have not kept any records on certain things. I do understand, ...
6
votes
1
answer
26k
views
HP Smart Array P420i Array Management in ESXi 5.5
I have a HP DL380p Gen8 server with ESXi 5.5 running on it and HP Smart Array P420i. I've installed 4 new hard disks on it and want to put them in a RAID 6 array (Although RAID 10 would be OK too).
...